What I actually run today: Strata + Hermes on three machines
Routes A, B and C solve "llama.cpp on AMD". This page documents what runs on my desks now — one level up the stack — and why I would call it the recommended configuration after you have learned the three routes.
What Strata is
Strata is a free, open-source inference engine for running the Qwen3.8-Flash-Next family on consumer NVIDIA and AMD cards — RTX 20/30/40/50-series and Radeon RX 7000/9000 (its docs state 12 GB+ VRAM and 32 GB+ system RAM as the baseline). It ships as a desktop app and a local server with an API that is both OpenAI- and Anthropic-compatible:
GET http://127.0.0.1:8080/v1/models # model IDs before wiring anything POST http://127.0.0.1:8080/v1/chat/completions # OpenAI-compatible POST http://127.0.0.1:8080/v1/messages # Anthropic-compatible GET http://127.0.0.1:8080/health # server status
Two practical notes from its docs: the server binds to 127.0.0.1 only by default (LAN exposure is a deliberate choice, below), and port 8080 collides with a manually started llama-server — Strata can be moved with --port.
Install: one step, plus one firewall rule
Honest experience, notes dated 2026-11-11: if you follow the installer correctly, that is genuinely all there is to it. The Windows installer does not need admin rights; the repo also documents a one-line terminal install for Windows (PowerShell) and Linux/macOS. The only configuration work was letting the LAN reach port 8080 — Strata's own docs suggest exactly this rule:
New-NetFirewallRule -DisplayName "Strata 8080" ` -Direction Inbound -Action Allow -Protocol TCP -LocalPort 8080 ` -Profile Private
Same discipline as the llama.cpp routes: Private profile only. If you want a tighter scope than "all private networks", narrow the rule's remote-address list to your LAN subnet — see Route A's firewall section.
The three-machine shape
| Machine | Hardware (class only) | Runs | Job |
|---|---|---|---|
| PC1 | desktop · RX 9070 XT | Strata server — main model | chat + coding inference |
| PC2 | desktop · RX 9060 XT | Strata server — compression model | context compression only |
| PC3 | NUC-class mini PC (integrated graphics, no discrete GPU) | Hermes Desktop + agent, MCP servers, tools | never runs inference |
Hermes Desktop + agent (PC3)
|
+-- main model -> Strata :8080 on PC1 (RX 9070 XT)
+-- compression -> Strata :8080 on PC2 (RX 9060 XT)
Why three boxes when two inference machines sound extravagant: a long session triggers context compression mid-conversation, and compression running on the same GPU as the main model steals inference throughput at exactly the wrong moment. Giving compression its own card keeps both smooth, and moving inference off the agent box keeps the agent responsive no matter how hard the GPUs work. The honest caveat: these models are RAM-hungry (Strata's docs: 32 GB minimum) — my boxes carry more system RAM than a typical desktop, and that is part of why this shape works. A single big box running both roles is fine until sessions get long; check GPU utilization during a compression step before deciding you need PC2.
Wiring Hermes to two inference boxes
Hermes (the agent this site's author runs daily) takes custom OpenAI-compatible providers in its config, with API keys kept in an .env file rather than the YAML. The shape, generalized (machine names never appear here; addresses are IETF documentation ranges):
providers:
custom:main-strata:
base_url: http://192.0.2.11:8080/v1 # PC1
key_env: HERMES_CUSTOM_MAIN_STRATA_API_KEY
custom:compress-strata:
base_url: http://192.0.2.12:8080/v1 # PC2
key_env: HERMES_CUSTOM_COMPRESS_STRATA_API_KEY
model:
default:
provider: custom:main-strata # chat + coding go to PC1
auxiliary:
compression:
provider: custom:compress-strata # compression goes to PC2
Two lessons from the notes. First, keys go in %LOCALAPPDATA%\hermes\.env (or ~/.hermes/.env on Linux), referenced by environment-variable name — the config file stays shareable. Second, pinning providers by IP instead of machine name makes troubleshooting shorter: name resolution adds a failure mode you don't need on a private LAN.
Verify: hermes doctor, then watch utilization
The check that proves the split actually works:
hermes doctor # ✓ Auxiliary task routing resolved: compression -> custom@compress-strata # ✓ API connectivity passed: provider 'custom@compress-strata' reachable # ✓ Config integrity passed: no issues found
Then the behavioral test: during a long session, watch PC2's GPU utilization spike when compression fires, and PC1's spike during normal chat. If compression never hits PC2, your routing is not what you think it is.
The time config broke, and how it came back
A real incident worth repeating: during a config edit, one provider entry vanished — hermes doctor said the API keys and routing were fine, but hermes model listed only the cloud provider and the custom box looked "not recognized". It was not a network failure: the config file itself had lost the entry. Diagnosis was Get-Content config.yaml on the raw file (the doctor validates what exists; only the raw file shows what is missing). Recovery was re-adding the provider block; after that, every doctor check passed again. The habit it taught: before editing inference settings, snapshot config.yaml to config.yaml.bak and .env to .env.bak. Five seconds, and the recovery is a copy-paste instead of an archaeology dig.
Why this is "recommended after A/B/C"
- Routes A/B/C teach you the plumbing — GPU targets, VRAM/RAM paging, TDR, firewall scope. Strata packages that plumbing away, but when something breaks (a new card, a quant that won't fit, a build that regressed) the routes tell you where to look.
- The managed install removed the daily friction: no manual builds, no nightly-pin upkeep, one API surface for several models.
- The three-machine split fixes the one scaling problem a single box shows: compression eating the main model's GPU mid-session.
Related reading
- llama.cpp on AMD Radeon in 2026: The Three Routes That Actually Work
- A 125-Billion-Parameter Model on Two Ordinary PCs: The Build, the Numbers, and the Failure
- I Let Three Local LLMs Read 116 Lines of Legacy VBA: Every Rule Found, None of the Reasons
Honesty note. The three-machine configuration is from my notes dated 2026-11-11; the incident story is from the same period. There are no tok/s measurements for the Strata setup anywhere on this site — the qualitative claims (installer was one step; compression offloads the main GPU) are my observations. External facts — Strata's repo, hardware requirements, API endpoints, the Windows installer being admin-free — were checked against the project's repository on 2026-11-12 and will move; re-verify before copying commands. Machine names, host names and private addresses appear nowhere: 192.0.2.11/.12 are IETF documentation addresses, and provider/env names are generalized. No affiliate links in this article.